logo
products
PRODUCTS DETAILS
Home > Products >
MTP to LC / SC / ST / FC Fiber Truck Cable , 12 Standard Harness Fiber Patch Cord

MTP to LC / SC / ST / FC Fiber Truck Cable , 12 Standard Harness Fiber Patch Cord

MOQ: 100 pcs
Price: 0.2USD-100USD
Standard Packaging: 1 pc/ box, 160 pcs/carton box
Delivery Period: 7days after payment
Payment Method: Western Union, T/T
Supply Capacity: 10,000 pcs per month
Detail Information
Place of Origin
china
Brand Name
YINGDA
Certification
ISO SGS ROHS
Model Number
MPOf-12LC-OM2-03
Connector:
MPO Female
Fiber Type:
OM2 50/125um
Cable Type:
Bundle Cable
Fiber Count:
12 Fibers LC
Insertion Loss:
<0.3dB
Package:
Vacuum Packing
Highlight:

MPO fanout cable

,

MPO patch cord

Product Description

12 Fibers MTP to LC / SC / ST / FC truck cable, 12 Standard - MTP Breakout Harness Cable

 

 

MTP is the high dense degree of optical fiber pre-connect system, which is generally use in three areas: 

The data centra application with high dense degree environment, 

The optical fiber to the building

The internal connector application in fiber equipment such as Splitter, 40G / 100G SFP and SFP+

 

YINGDA MTP fiber patch cable is compliant to IEC-61754-7 and TIA-604-5(FOCIS-5) standard.

 

MTP to LC / SC / ST / FC Fiber Truck Cable , 12 Standard Harness Fiber Patch Cord 0

 

MTP&MPO Difference

The term MTP is a registered trademark of US Conec, which have became the tendency in 

Europe&American fiber communications areas at present.

 

MTP to LC / SC / ST / FC Fiber Truck Cable , 12 Standard Harness Fiber Patch Cord 1

 

Notes:
Please kindly to choice the best one for your project from above the two kinds of 8 fiber MTP 

harness cable array methods.
In the 40/100GbE project, 8 optical fibers are required.

 

Assembly Structure Illustration

MTP to LC / SC / ST / FC Fiber Truck Cable , 12 Standard Harness Fiber Patch Cord 2

          12-Fiber Mini-Core Cable structure

 

Specification:

 

Single mode

Multimode

Insertion Loss

≤0.3dB

≤0.3dB

Return Loss

≥50dB (PC)

≥20dB

Repeatability

≤0.1

≤0.1

Durability

≤0.2 dB typical change, 1000 matings

≤0.2 dB typical change, 1000 matings

Interchangeability

≤0.2dB

≤0.2dB

Tensile strength

≥10kg

≥10kg

Operating Temperature

-40 to + 80°C

-40 to + 80°C

Storage Temperature

-40 to + 80°C

-40 to + 80°C

 

 

MTP Hybrid Harnesses Fiber Patch Cables are terminated with MTP connector on one end 

and other end with LC, FC, SC, ST, or MTRJ connectors to meet a variety of fiber cabling 

requirements.


1. The default diameter of the MTP cable is 3.0mm.
2. The diameter of branch cable could be choose as 0.9mm,2.0mm

3. YINGDA can also custom the pulling eyes /plug on request.

 

MPO - LC12 Patch Cord Jumper MM 50/125UM 2.0MM Round LSZH G657A1 2Meters More Pictures

MTP to LC / SC / ST / FC Fiber Truck Cable , 12 Standard Harness Fiber Patch Cord 3

  1. Cable diameter: 2,0mm bundle cable, color: orange
  2. multimode fiber:50/125,62.5/125um,, OM3 ,OM4 cable available
  3. Cable can be changed into ribbone fibers,on customer request
  4. Fiber count can be: 8fibers, 12fibers or 24fibers all can make
  5. Connectors: SC, LC, ST,FC, etc; MPO/MTP
  6. MPO Connectors: female or male

MTP to LC / SC / ST / FC Fiber Truck Cable , 12 Standard Harness Fiber Patch Cord 4

Fanout kits: heatshrinkable fanout kits round type, square type breakout kits can be used.

 

 

MTP to LC / SC / ST / FC Fiber Truck Cable , 12 Standard Harness Fiber Patch Cord 5 

Out pigtails can be bundle 12cores colorful standard, 0.9mm too, on customer request.

 

Ratings & Review

Overall Rating

5.0
Based on 50 reviews for this supplier

Rating Snapshot

The following is the distribution of all ratings
5 stars
0%
4 stars
0%
3 stars
0%
2 stars
0%
1 stars
0%

All Reviews

1
1*A
Canada Apr 28.2025
Excellent product, complete Items as specified. Special thanks to ms. Milla for such Great service.
O
O*x
Indonesia Feb 7.2025
Everything excellent, from the treatment in the negotiation, delivery time, and the quality of their product very good Delivery: 100% Quality: 100% Design: 100% Service: 100%
1
1*x
Chile Aug 23.2023
Good quality, IP65 waterproof. will continue to cooperate with YINGDA
products
PRODUCTS DETAILS
MTP to LC / SC / ST / FC Fiber Truck Cable , 12 Standard Harness Fiber Patch Cord
MOQ: 100 pcs
Price: 0.2USD-100USD
Standard Packaging: 1 pc/ box, 160 pcs/carton box
Delivery Period: 7days after payment
Payment Method: Western Union, T/T
Supply Capacity: 10,000 pcs per month
Detail Information
Place of Origin
china
Brand Name
YINGDA
Certification
ISO SGS ROHS
Model Number
MPOf-12LC-OM2-03
Connector:
MPO Female
Fiber Type:
OM2 50/125um
Cable Type:
Bundle Cable
Fiber Count:
12 Fibers LC
Insertion Loss:
<0.3dB
Package:
Vacuum Packing
Minimum Order Quantity:
100 pcs
Price:
0.2USD-100USD
Packaging Details:
1 pc/ box, 160 pcs/carton box
Delivery Time:
7days after payment
Payment Terms:
Western Union, T/T
Supply Ability:
10,000 pcs per month
Highlight

MPO fanout cable

,

MPO patch cord

Product Description

12 Fibers MTP to LC / SC / ST / FC truck cable, 12 Standard - MTP Breakout Harness Cable

 

 

MTP is the high dense degree of optical fiber pre-connect system, which is generally use in three areas: 

The data centra application with high dense degree environment, 

The optical fiber to the building

The internal connector application in fiber equipment such as Splitter, 40G / 100G SFP and SFP+

 

YINGDA MTP fiber patch cable is compliant to IEC-61754-7 and TIA-604-5(FOCIS-5) standard.

 

MTP to LC / SC / ST / FC Fiber Truck Cable , 12 Standard Harness Fiber Patch Cord 0

 

MTP&MPO Difference

The term MTP is a registered trademark of US Conec, which have became the tendency in 

Europe&American fiber communications areas at present.

 

MTP to LC / SC / ST / FC Fiber Truck Cable , 12 Standard Harness Fiber Patch Cord 1

 

Notes:
Please kindly to choice the best one for your project from above the two kinds of 8 fiber MTP 

harness cable array methods.
In the 40/100GbE project, 8 optical fibers are required.

 

Assembly Structure Illustration

MTP to LC / SC / ST / FC Fiber Truck Cable , 12 Standard Harness Fiber Patch Cord 2

          12-Fiber Mini-Core Cable structure

 

Specification:

 

Single mode

Multimode

Insertion Loss

≤0.3dB

≤0.3dB

Return Loss

≥50dB (PC)

≥20dB

Repeatability

≤0.1

≤0.1

Durability

≤0.2 dB typical change, 1000 matings

≤0.2 dB typical change, 1000 matings

Interchangeability

≤0.2dB

≤0.2dB

Tensile strength

≥10kg

≥10kg

Operating Temperature

-40 to + 80°C

-40 to + 80°C

Storage Temperature

-40 to + 80°C

-40 to + 80°C

 

 

MTP Hybrid Harnesses Fiber Patch Cables are terminated with MTP connector on one end 

and other end with LC, FC, SC, ST, or MTRJ connectors to meet a variety of fiber cabling 

requirements.


1. The default diameter of the MTP cable is 3.0mm.
2. The diameter of branch cable could be choose as 0.9mm,2.0mm

3. YINGDA can also custom the pulling eyes /plug on request.

 

MPO - LC12 Patch Cord Jumper MM 50/125UM 2.0MM Round LSZH G657A1 2Meters More Pictures

MTP to LC / SC / ST / FC Fiber Truck Cable , 12 Standard Harness Fiber Patch Cord 3

  1. Cable diameter: 2,0mm bundle cable, color: orange
  2. multimode fiber:50/125,62.5/125um,, OM3 ,OM4 cable available
  3. Cable can be changed into ribbone fibers,on customer request
  4. Fiber count can be: 8fibers, 12fibers or 24fibers all can make
  5. Connectors: SC, LC, ST,FC, etc; MPO/MTP
  6. MPO Connectors: female or male

MTP to LC / SC / ST / FC Fiber Truck Cable , 12 Standard Harness Fiber Patch Cord 4

Fanout kits: heatshrinkable fanout kits round type, square type breakout kits can be used.

 

 

MTP to LC / SC / ST / FC Fiber Truck Cable , 12 Standard Harness Fiber Patch Cord 5 

Out pigtails can be bundle 12cores colorful standard, 0.9mm too, on customer request.

 

sitemap |  Privacy Policy | China Good Quality Fiber Optic Termination Box Supplier. Copyright © 2015-2026 YINGDA TECHNOLOGY LIMITED . All Rights Reserved.